Secutron MR-2400 Addressable Control Panel |
|
|
|
|
Jan 17, 2005 at 06:05 PM |
|
The
MR-2400 fire alarm system control unit is the heart of a
sophisticated microprocessor-based fire alarm system. Employing
addressable input circuits with addressable analog detectors, and
monitoring and control modules, the MR-2400 is ideally suited to
fit the varied needs of residential, commercial, industrial, and
institutional applications.
The MR-2400 provides up to 2 Style6 (ClassA) addressable or 4
Style4 (ClassB) addressable circuits, 2 general purpose FormC relays
and 6 polarity reversing notification appliance (bell) circuits as well
as system operated relays for alarm and trouble indication.
The MR-2400 can use a MR-2944 series annunciator for remote
control and display. The MR-2944 can contain up to 576 LEDs (192
zones) for annunciation, an LCD display for messages, and 16
pre-defined switch inputs for control functions. The MR-2944 can
use any of the MR-2902, MR-2622, or MR-2915 boards for
interfacing to the LEDs. Using the MR-2944 requires that the
MR-2400 have the MR-2109-2 communications module installed.

The MR-2400 can use a MR-2614 series annunciator for
remote control and display. The MR-2614 can contain up to 216
LEDs (72 zones) for annunciation and 4 pre-defined switch inputs
for control functions. The MR-2614 can use any of the
MR-2902, MR-2622, or MR-2915 boards for interfacing to the LEDs.
The MR-2614 connects to the annunciator port on the MR-2400.
Download data sheet.
- UL, ULC, CSFM, and MEA Listed
- UL Central Station Connection
- UL Listed for Releasing Service
- CSFM High Rise Listed
- 5 year warranty
- Sophisticated capabilities yet simple to operate
- Addressable detection circuits
- Adjustable sensitivity
- Day/night sensitivity
- Two-stage alarm capability
- One-person system test capability
- Totally software driven
- Field programmable via PC
- Passcode protection
- History log ≈≈900 events
- System alarm and trouble relays
- Remote alarm and trouble annunciation
- LCD supertwist 80 character (4 x 20) backlit display
- Sprinkler supervision
- Ground fault indication by supervised circuit
- Cross-zoned releasing circuit
- Addressable input circuits Style4 (ClassB) or Style6 (ClassA)
- StyleY (ClassB) or StyleZ (ClassA) notification appliance (bell) circuits
- Power limited circuits
- 'Hot Key' system controls
- Display of real time
- Signal silence inhibit
- Signal time limit cut-out
- Alarm verification by device
|
|