Description
The MR-2616 is a microprocessor based fire alarm control unit with 16 zones for conventional fire detection devices.
Front Panel
The front panel consists of 5 system LEDs, 16x3 zone LEDs and 6
function keys. The 5 system LEDs provide common indication of alarm,
ground fault, trouble, supervisory, and AC power. LEDs will flash with
a new condition and will remain on steady after acknowledgement.
The zone LEDs consist of a red alarm LED, amber supervisory LED, and a
yellow trouble LED for each input circuit. LEDs will flash with a new
condition and will remain on steady after acknowledgement.
Function keys provide the following functions : acknowledge, signal
silence, system reset, test mode, lamp test, and city disconnect. Each
function key has 2 LEDs to indicate status.
Input Circuits
Input circuits are individually software definable for contact devices
only, smoke detectors only, or combination of smoke detectors and
contact devices. Circuits defined for smoke detector and contact
devices are able to differentiate between smoke detector operation and
contact device operation, which permits combining contact and smoke
detectors on one common circuit when the alarm verification feature is
used. The circuits are further definable for alarm or supervisory.
Circuits can support Style B (Class B) or StyleD (Class A) wiring. An additional add-on module is required for Style D wiring.
Ground faults are indicated by circuit.
Output Circuits
The MR-2616 includes 6 supervised polarity reversing notification
appliance (bell) circuits, 2 general purpose relays in Style B
configuration or 8 relays in StyleD configuration, and 2 system
operated relays for alarm and trouble indication. Ground faults are
indicated by notification appliance (bell) circuit.
The general purpose relays can be programmed for normally open or normally closed operation.
The system relays are for alarm and trouble indication. The trouble
relay is normally energized to allow for indication of both AC power
and battery power loss.
Features
UL, CSFM and MEA Listed
5 year warranty
Conventional input circuits Style B (Class B) or Style D (Class A)
System alarm and trouble relays Alarm, supervisory, and trouble LEDs for each zone
Custom labels per zone
Alarm verification by zone
Ground fault indication by input circuit
Programmable input circuits
Two stage alarm capability
Totally software driven
Field programmable via service terminal
Optional remote annunciator
‘Hot Key’ system controls
Signal silence inhibit
Signal time limit cut-out

Model Description
MR-2616
Sixteen Zone Fire Alarm Control Panels MR-2616B Sixteen Zone Fire Alarm Control Panel, Class B, Beige
MR-2616BE
Sixteen Zone Fire Alarm Control Panel, Class B, 240VAC, Beige
MR-2616R
Sixteen Zone Fire Alarm Control Panel, Class B, Red
MR-2616RE
Sixteen Zone Fire Alarm Control Panel, Class B, 240VAC, Red
MR-2616B-A
Sixteen Zone Fire Alarm Control Panel, Class A, Eight Relays, Beige
MR-2616BE-A
Sixteen Zone Fire Alarm Control Panel, Class A, Eight Relays, 240VAC, Beige
MR-2616R-A
Sixteen Zone Fire Alarm Control Panel, Class A, Eight Relays, Red
MR-2616RE-A
Sixteen Zone Fire Alarm Control Panel, Class A, Eight Relays, 240VAC, Red
Accessories
MR-2614EHS/MR-2622S
Remote Annunciator unit c/w board
MR-2614EH
Enhanced Remote Annunciator board MR-2915 LED Driver for Annunciators
MR-2622
Annunciator strip, 3 x 8 LEDs
MR-2976B
Flush Trim, Beige
MR-2976R
Flush Trim, Red
|